Enter the New World of MiCOM S1 Studio Welcome to MiCOM S1 Studio, a major advance of the MiCOM S1 Setting Software for Automation products. MiCOM S1 Studio will make your life easier by providing integrated configuration and monitoring features. It has an intuitive and versatile interface with file management facilities. The current MiCOM S1 Studio brings enhanced usability while preserving the rich features of its previous versions. MiCOM S1 Studio Software Request A link to download the MiCOM S1 studio software can be found by clicking Software/Firmware in the Downloads menu. Installation Guideline for Upgrading (Maintaining Installed Data Models) As you can run only one MiCOM S1 Studio installation on your PC, you first need to remove an older version.
For your search query Mqm Pakistan MP3 we have found 1000000 songs matching your query but showing only top 10 results. First search results is from YouTube which will be first converted, afterwards the file can be downloaded but search results from other sources can be downloaded right away as an MP3 file without any conversion or forwarding. Please Note: Before downloading you can preview any song by mouse over the Play button and click Play or Click to Download button to download hd quality mp3 files. Mqm video. Now we recommend you to Download first result Hai Muhajir Ki Shan MQM Pakistan MP3 which is uploaded by R B of size 6.54 MB, duration 4 minutes and 58 seconds and bitrate is 192 Kbps.
Key features in the MiCOM S1 family: Alstom Grid's integrated engineering tool that provides users with access to all automation IED configuration and record data. MiCOM S1 Studio - IED Support. Welcome to the Schneider Electric Website. Welcome to our website. Do not agree to launch the Data Model Manager. MiCOM S1 Studio Software Free Download. MiCOM S1 Agile Software Free Download Data Model Patch. SEL Software Free Download SEL Database. GE Relay software.
P40 Agile can be used to monitor the integrity of the breaker coils and circuits with support for various TCS schemes. Advanced Communications Two communication ports are standard: a rear port providing remote communications and a front port for substation staff. The front USB port allows the programming of settings, configuration of the programmable scheme logic, extraction and viewing of event, disturbance and fault records, viewing of measurements and the instigation of control functions. Supported Protocols: • Courier / K-Bus • Modbus • IEC 60870-5-103 • DNP 3.0 (RS485 serial or Ethernet) • IEC 61850 (100 Mbit/s Ethernet) IEC 61850 or DNP 3.0 over Ethernet are available when the optional Ethernet port is ordered in 30TE and 40TE models. Redundant Ethernet protocol PRP, HSR and RSTP are also available in dual RJ45 or dual fiber. The copper physical link option uses RJ45 connectors, the fiber option uses LC connectors.
• P341/EN AD/F43 Update Documentation MiCOM P341. • Update Documentation P341/EN AD/F43 MiCOM P341 (AD) -1 P341 UPDATE DOCUMENTATION Since versions 0300 & 0310J, several changes on existing features have been added. These are described with reference to the documentation listed below: Release Version Documentation P341/EN M/F33 Technical Manual Document Ref. • P341/EN AD/F43 Update Documentation (AD) -2 MiCOM P341 Document Ref.
Agile P14N, P14D, P94V P40 Agile Feeder Management The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigour and technology of transmission applications to the entire utility and industrial market. The footprints of both the device physical size and the lifecycle environmental impact have been minimised using state-of-the-art design, component, and process selection. Agile solutions from GE are ideal for new-build and retrofit alike. Agility and Versatility MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for a wide variety of applications in solidly-earthed, resistance-earthed and Petersen coil systems alike. Key Benefits • Comprehensive current, voltage, power and frequency protection • Multi-stage independent protection elements • Two stage circuit breaker failure and breaker condition monitoring • Switchgear supervision including CT/VT, DC supply, full trip circuit supervision • Support for multiple industry standard communication protocols including IEC 61850 • Compact, withdrawable design with 4”, 6”, and 8” case sizes for reduced space applications.
Use Windows® Control Panel to call the MiCOM S1 Studio setup wizard. • Press ‘Yes’ when asked whether you want to remove the application and all pertaining features. • Press ‘No’ when asked whether you want to remove the data models from your disk. • The wizard will remove all programs of MiCOM S1 Studio. • Close the wizard, close the Control Panel. • Run the new MiCOM S1 Studio installation executable.
Micom S1 Agile
No-longer are separate tools required for redundant Ethernet configuration, scheme operational dashboards, programmable curve profiles or automatic disturbance record extraction – all applications are embedded. MiCOM S1 Agile Universal IED Engineering Toolsuite. Flexible Hardware Platform • Space-saving 4U height and 20TE (4'), 30TE (6') or 40TE (8') case sizes • A front USB port and a rear RS485 port • Power-up diagnostics and continuous self-monitoring • Wide choice of opto-isolated binary inputs and output relays • N/O (form A) and N/C (form B) watchdog contacts • Field upgradeable to change the relay model avoiding costly hardware change via firmware upgrade The front-panel interface allows direct IED interaction. A USB front port offers enhanced access by laptop computers. Integrated user function keys and tri-color programmable LEDs provide a cost-effective solution for control and annunciation. Numerous, optional, modern communication protocols, including IEC 61850, ensure interfacing to upper-level Supervisory, Control, Automation or Data Acquisition systems. K-Series to P40 Agile Retrofit Upgrade Many distribution utilities have a large installed base of 1st generation numerical K-series relays.
• Close the wizard, close the Control Panel. • Run the new MiCOM S1 Studio installation executable. • Select all options as done for the installation before. • Do not agree to launch the Data Model Manager. As soon as the wizard finishes, you are able to launch MiCOM S1 Studio and open your existing projects. User Programmable Curve Tool Application Software: The User Programmable Curve Tool provides the following features: • Creation of user-defined curves and flexible download/upload of operating and reset curves into/from MiCOM Px4x range of relays. • User-friendly graphical user interface for easy creation and visualization of curves either by inputting formula or data points.
K-Series to P40 Agile Retrofit Upgrade Many distribution utilities have a large installed base of 1st generation numerical K-series relays. A fast retrofit upgrade is required to replace with modern P40 Agile relays, in the minimum of downtime. The new relays need zero or minimal configuration as the K-series “as-fitted” settings are extracted and automatically converted to match the new Agile relays. Configuration and injection testing is doneaway from the destination feeder, in a spare case. The device is pin-to-pin compatible with the legacy relay case which is left intact - no wiring is disturbed, and the feeder outage time is less than 5 minutes.
Most of my closest friends and family relatives know that I have the history of always forgetting things and most especially passwords. Winrar 64 bit windows 10. I'm really thankful for this kind of software!
Enter the New World of MiCOM S1 Studio Welcome to MiCOM S1 Studio, a major advance of the MiCOM S1 Setting Software for Automation products. MiCOM S1 Studio will make your life easier by providing integrated configuration and monitoring features. It has an intuitive and versatile interface with file management facilities. The current MiCOM S1 Studio brings enhanced usability while preserving the rich features of its previous versions. MiCOM S1 Studio Software Request A link to download the MiCOM S1 studio software can be found by clicking Software/Firmware in the Downloads menu. Installation Guideline for Upgrading (Maintaining Installed Data Models) As you can run only one MiCOM S1 Studio installation on your PC, you first need to remove an older version. Use Windows® Control Panel to call the MiCOM S1 Studio setup wizard.
Up to 2048 time-tagged event records are stored in the flash memory and can be extracted using the communication ports or viewed on the front panel display. Records of the last 10 faults are stored in the flash memory. Fault data is also available via IEC 61850 protocol. The internal disturbance recorder has up to 9 analogue channels, 64 digital channels and 1 time channel.
• The wizard will remove all programs of MiCOM S1 Studio. • Close the wizard, close the Control Panel. • Run the new MiCOM S1 Studio installation executable. • Select all options as done for the installation before.
• Press ‘Yes’ when asked whether you want to remove the application and all pertaining features. • Press ‘No’ when asked whether you want to remove the data models from your disk. • The wizard will remove all programs of MiCOM S1 Studio.
Enter the New World of MiCOM S1 Studio Welcome to MiCOM S1 Studio, a major advance of the MiCOM S1 Setting Software for Automation products. MiCOM S1 Studio will make your life easier by providing integrated configuration and monitoring features. It has an intuitive and versatile interface with file management facilities. The current MiCOM S1 Studio brings enhanced usability while preserving the rich features of its previous versions. MiCOM S1 Studio Software Request A link to download the MiCOM S1 studio software can be found by clicking Software/Firmware in the Downloads menu. Installation Guideline for Upgrading (Maintaining Installed Data Models) As you can run only one MiCOM S1 Studio installation on your PC, you first need to remove an older version. Use Windows® Control Panel to call the MiCOM S1 Studio setup wizard.
The logic includes OR, AND and majority gates, timers, and set/reset latch functions, with the ability to invert the inputs and outputs, and provide feedback. The relay has 32 PSL timers could be conveniently configured in PSL, setting or from the relay front panel. The PSL imposes no delay on logic throughput, using concurrent processing being used instead of sequential equations and avoiding any logic ‘race’ issues. P14D Functional Block Diagram. Key Features • Comprehensive metering & power-up diagnostics • Two stage circuit breaker failure and breaker condition monitoring • Switchgear supervision including CT/VT, DC supply, full Trip Circuit Supervision, CB failure • Switch control and status (up to 8) and up to 2048 events and 10.5 s disturbance records Metering, Monitoring & Diagnostics All events, fault and disturbance records are time tagged to a resolution of 1 ms.
Engineering Tool Suite Discover the next generation in tools for configuration and maintenance of MiCOM – redefining MiCOM S1. S1 Agile is the next step enhancement from existing MiCOM S1 Studio, encompassing all of the traditional functionality, to become the complete successor. The move from S1 Studio to S1 Agile underlines Alstom’s R&D investment in usability: to assemble all tools in a palette for simple entry, with intuitive navigation via fewer mouse-clicks. S1 Agile is the truly universal PC tool for MiCOM for the first time. No-longer are separate tools required for redundant Ethernet configuration, phasor measurement unit commissioning, busbar scheme operational dashboards, programmable curve profiles or automatic disturbance record extraction – all applications are embedded. MiCOM S1 Agile supports all existing MiCOM, K-Series and Modulex, including a utility for automatic conversion of setting files from previous generations of numerical relays like K-series and MiCOM P20 to the latest P40 Agile models. To move to the future, with no loss of functionality, no loss of device support, and full compatibility with your installed base and system architecture – request a copy of S1 Agile with the contact form link below.
Key Features • Comprehensive current, voltage, power and frequency protection functions • Multi-stage independent protection elements, variety of curves in 4 setting groups • High Impedance Fault, Load Encroachment, Switch onto fault and Fault Locator • Rate of change, full-scheme auto-reclose, TEFD and synchrocheck Protection & Control The P14N non-directional feeder, P14D directional feeder and P94V voltage and frequency IEDs bring the design rigor and technology of transmission applications to the entire utility and industrial market. P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors and distributed generation is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up).
Section Page No. Description P341/EN SC/F33 Network connectivity continued 9.3.2.2 New section The data model of MiCOM relays New section The communication services of MiCOM relays New section Peer-to-peer (GSE) communications New section Scope 9.6.1 New section IEC 61850 GOOSE configuration 9.6.2. • Update Documentation P341/EN AD/F43 MiCOM P341 (AD) -1 TECHNICAL DATA (P341/EN TD/F33) • EIA(RS)485 signal levels, two wire connections located on general purpose block, Design M4 screw. Modular MiCOM Px40 platform relay, P341 in For screened twisted pair cable, multidrop, 40TE case. Mounting is front of panel flush 1000m max.
Mounting, or 19“ rack mounted with rack frame For K-Bus, IEC-60870-5-103, MODBUS or (ordering options). • Update Documentation P341/EN AD/F43 MiCOM P341 (AD) -7 AC Current Power Supply Interruption Nominal current (In): 1 and 5 A dual rated. Per IEC 60255-11: 1979: (1A and 5A inputs use different transformer tap The relay will withstand a 20ms interruption. • P341/EN AD/F43 Update Documentation (AD) -8 MiCOM P341 Output Contacts Standard Contacts Environmental Conditions General purpose relay outputs for signaling, tripping and alarming: Ambient Temperature Range Rated voltage: 300 V Per IEC 60255-6: 1988: Continuous current: 10 A Operating temperature range: Short-duration current: 30 A for 3 s -25°C to +55°C (or -13°F to +131°F) • Update Documentation P341/EN AD/F43 MiCOM P341 (AD) -9 Between all independent circuits. Immunity to Radiated Electromagnetic Between all independent circuits and Energy protective (earth) conductor terminal. Per IEC 60255-22-3: 2000, Class III: Test field strength, frequency band 80 to 1000 Between the terminals of independent circuits.
Configuration and injection testing is doneaway from the destination feeder, in a spare case. The device is pin-to-pin compatible with the legacy relay case which is left intact - no wiring is disturbed, and the feeder outage time is less than 5 minutes.
Up to 2048 time-tagged event records are stored in the flash memory and can be extracted using the communication ports or viewed on the front panel display. Records of the last 10 faults are stored in the flash memory. Fault data is also available via IEC 61850 protocol.